MINIPROX HAZARDOUS LOCATION DOOR ACCESS
Datamine provide Singapore most cheap and reliable miniprox hazardous location access system.
Typical maximum* read range |
---|
ProxCard® II card - up to 5.5" (14 cm) ISOProx® II card - up to 5" (12.5 cm) ProxKey™ II keyfob - up to 2" (5 cm) ProxCard® Plus card - up to 2" (5 cm) SmartProx™ II card - up to 5" (12.5 cm) *Depending on local installation conditions. | Dimensions |
6.0" x 1.7" x 1.0" (15.2 x 4.3 x 2.54 cm) | Material |
Polycarbonate UL 94 | Power supply |
Standard MiniProx: 5.1-16 VDC Haz. Loc. MiniProx: 5.1-16 VDC Linear power supplies are recommended. | Current requirements |
Average: 40 mA (5 VDC); 50 mA (12 VDC) Peak: 60 mA (5 VDC); 120 mA (12 VDC) | Operating temperature |
-22° to 150° F (-30° to 65° C) | Operating humidity |
0-95% relative humidity non-condensing | Weight |
With terminal strip 3.5 oz. (99 gm) With pigtail 3.8 oz. (108 gm) Haz. Loc. MiniProx: 3.8 oz. (108 gm) | Transmit frequency |
125 kHz | Excite frequency |
125 kHz | Certifications |
Canada/UL 294 Listed: Access Control System Units Canada/UL 1604 Listed (with Haz. Loc. junction box only): Hazardous Locations Class I, Div. 2, Groups A,B,C,D. FCC Certification, United States Canada Certification CE Mark, Europe UK Type Approval Germany Type Approval Australia C-Tick Mark New Zealand EMC | Cable distance |
Wiegand interface: 500 feet (150 m) Clock-and-data interface: 50 feet (15 m) Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control. |